Yes, an existing gas line may be extended or branched if a licensed gasfitter confirms that the full installation is sound, compliant and able to supply the combined appliance demand. This assessment is essential when replacing an electric cooktop with gas or adding any new gas appliance.
There is no standard gas line size for a gas cooktop. An appropriately licensed NSW gasfitter must calculate the required size from the cooktop’s maximum gas consumption in MJ/h, pipe length and material, available pressure, gas type and demand from other connected appliances.
What determines the pipe size?
The gasfitter assesses:
- Appliance demand: The cooktop’s data plate or manufacturer’s instructions state its maximum gas consumption and required inlet pressure.
- Pipework: Developed length, material, internal diameter, fittings and branches affect capacity and pressure loss.
- Other appliances: Shared pipe sections must carry the combined demand of the appliances they supply.
- Supply conditions: Natural gas and LPG have different characteristics and supply conditions, so their sizing requirements are not interchangeable.
The gasfitter uses the applicable pipe-sizing provisions of AS/NZS 5601.1 (the Australian gas installations standard that governs safe pipe diameters, allowable pressure drops, and appliance clearances to prevent gas starve and hazard), together with the appliance instructions and piping-system requirements. Cooktop width and burner count alone cannot determine the correct size.
Is 22 mm gas pipe required?
No. A 22 mm copper pipe may suit part of some installations, but it is not universally required or necessarily adequate. Its capacity depends on the pipe’s internal bore, length, available pressure, gas type and downstream load. Other pipe materials use different dimensions and capacity data.
How is an existing line checked?
A licensed gasfitter identifies the full pipe route and material, confirms all connected appliance loads, calculates demand on each pipe section and verifies that the required pressure is available under operating conditions. Visible pipe diameter alone is not enough.
After alteration and testing, ask the gasfitter which NSW gas compliance documentation applies to the completed work.
Understanding gas line extension costs and on-site assessment
We don’t rely on generic online price tables or guesswork phone quotes because extending a gas service involves strict safety calculations and unique property layouts. Running copper through an accessible subfloor requires completely different time and materials compared to threading pipe through double-brick cavities, beneath concrete slabs, or across multi-storey dwellings. An on-site assessment allows a licensed gasfitter to test existing line pressure with a manometer, measure developed pipe lengths accurately, and calculate total connected megajoule (MJ/h) demand.
Our gasfitter breaks down every task and step involved — including pipe sizing, routing, compliant jointing, pressure testing, and issuing your NSW gas compliance certificate — so you understand the entire scope before work begins.
Do not size, alter, connect, test or commission gas pipework yourself. Gas work presents fire, explosion and carbon monoxide risks and requires an appropriately licensed gasfitter in NSW.
When you contact our team for a new gas point or extension, we ask a few targeted questions about your property type and appliance plans so our vehicle arrives prepared with the correct pipe sizes and diagnostic equipment. Contact our licensed gas point installation team for genuine guidance and a fixed upfront quote.